United Instruments LPC-10

$3,890.00

In stock

Compare
SKU: 25138CL Category:
  • United Instruments Model # LPC-10
  • Measurement Range: -1.5 to 11.5 H2O (-3.75 to 27.5 mbar)
  • Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical
  • Calibration Point Certainty: ± 0.012% Typical
  • Between Point Linearity: ± 0.01% Typical
  • Maximum Overpressure: 5 PSI (347 mbar)
  • Control Range: -10 to 10 H2O Standard (-25 mbar to 25 mbar)
  • System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale
  • (Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale
  • Stability: ± 0.05% of Full Scale/Year
  • Temperature Range: Operational: 0ºC to 50ºC, Calibrated: 10ºC to 30ºC, Storage: -20ºC to 50ºC
  • Input Power Requirements: 105-135 VAC/210-270 VAC—50/60 Hz @ 48 VA
  • Battery Operation: 2.2 AHr Self-Contained NiCad
  • Operational (50% duty): Approximately 2 Hours
  • Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2 ( 5mm) H
  • Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC, in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC, in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI
  • Indicators: Measure, Control, Program, Power, Standby, Battery
  • Digital Interface: Via RS232, 4800 Baud
  • Sensor Technology: Solid State, Piezoresistive Strain Gauge
  • Pressure Synthesis: Via Balanced Differential Piston Array, Servo Actuated Closed Loop Digitally Governed
  • Control Certainty: ± 0, -.015%
  • Auto Zero Certainty: Microprocessor Governed Via Electropneumatic Control (Resident in RAM) Better Than ± 0.005% of Full Scale
  • Calibration: Factory Calibrated Against NIST Traceable Standard
  • Dimensions & Weight: 10 Wide x 4.25 High x 8.25 Deep)
  • Warranty: 1 Year Parts & Labor (90 days for NiCad batteries)

>

Each Unit Includes

  • Manual
  • Line Cord
  • RS232 Cable
  • Manufacturers NIST Traceable Cert
    • United Instruments Model # LPC-10
    • Measurement Range: -1.5 to 11.5 H2O (-3.75 to 27.5 mbar)
    • Measurement Accuracy: ± 0.035% of Full Scale @ 25ºC (Includes zero, span, hysteresis and repeatability errors) Repeatability/Hysteresis: ± 0.015% Typical
    • Calibration Point Certainty: ± 0.012% Typical
    • Between Point Linearity: ± 0.01% Typical
    • Maximum Overpressure: 5 PSI (347 mbar)
    • Control Range: -10 to 10 H2O Standard (-25 mbar to 25 mbar)
    • System Accuracy: Lab Environment (@ 25ºC) ± 0.035% of Full Scale
    • (Combined Measure/Control) Field Operation (10 to 30ºC) ± 0.05% of Full Scale
    • Stability: ± 0.05% of Full Scale/Year
    • Temperature Range: Operational: 0ºC to 50ºC, Calibrated: 10ºC to 30ºC, Storage: -20ºC to 50ºC
    • Input Power Requirements: 105-135 VAC/210-270 VAC—50/60 Hz @ 48 VA
    • Battery Operation: 2.2 AHr Self-Contained NiCad
    • Operational (50% duty): Approximately 2 Hours
    • Display: 2 x 20 Alphanumeric Fluorescent Display: 0.2 ( 5mm) H
    • Units: in H2O @ 20ºC, in H2O @ 4ºC, mm H2O @ 20ºC, in H2O @ 4ºC, cm H2O @ 20ºC, cm H2O @ 4ºC, in Hg @ 0ºC, Torr (mm Hg), cm Hg @ 0ºC, mBar Pascal, kPascal, PSI
    • Indicators: Measure, Control, Program, Power, Standby, Battery
    • Digital Interface: Via RS232, 4800 Baud
    • Sensor Technology: Solid State, Piezoresistive Strain Gauge
    • Pressure Synthesis: Via Balanced Differential Piston Array, Servo Actuated Closed Loop Digitally Governed
    • Control Certainty: ± 0, -.015%
    • Auto Zero Certainty: Microprocessor Governed Via Electropneumatic Control (Resident in RAM) Better Than ± 0.005% of Full Scale
    • Calibration: Factory Calibrated Against NIST Traceable Standard
    • Dimensions & Weight: 10 Wide x 4.25 High x 8.25 Deep)
    • Warranty: 1 Year Parts & Labor (90 days for NiCad batteries)

    >

    Each Unit Includes

    • Manual
    • Line Cord
    • RS232 Cable
    • Manufacturers NIST Traceable Cert

    >

Brand

Instruments

United

Main Menu

United Instruments LPC-10

$3,890.00

Add to Cart